TL;DR: Use Oxygen Diffusers for an early algae-based supply, watch the algae stock and avoid adding Duplicants faster than you can support them. An operating diffuser produces 500 grams of oxygen per second, while a typical Duplicant consumes 100. Transition toward an Electrolyzer when you have reliable clean water, power, hydrogen handling and a cooling plan. Oxygen production and delivery are separate problems.
This Oxygen Not Included oxygen production guide covers the standard colony systems. Traits, DLC equipment and asteroid resources can change the best plan. Use your actual Duplicants’ consumption and the machine’s uptime rather than treating a nameplate output as guaranteed delivered oxygen.

On this page
Oxygen Not Included Oxygen Production: Count Demand First
Inspect how much oxygen your current colony consumes. The normal 100-grams-per-second reference is useful, but individual traits can change it. Adding a new Duplicant increases breathing demand alongside food and other resource needs.
Count usable production with downtime in mind. A building lacking power, input material or an open pressure environment produces nothing during that interval. A machine rated above your demand can still fail the colony if it spends much of the cycle idle.
Also inspect where the gas arrives. Breathable central rooms do not prove that distant bedrooms, work sites or suit docks receive enough. The oxygen overlay and machine status help separate an overall shortage from a distribution problem.
1. Start with Oxygen Diffusers
An Oxygen Diffuser consumes 550 grams of algae per second and produces 500 grams of oxygen per second while operating. It uses power and creates heat. At full uptime, its output equals the normal breathing demand of five ordinary Duplicants, before special consumption or delivery losses.
That reference is a planning ceiling, not a promise that one machine comfortably supports every five-person layout. Overpressure, algae delivery, power interruptions and gas access all reduce effective service. Give the machine a location where oxygen can spread to inhabited rooms.
The wiki notes that oxygen flows poorly through tight corridors. Airflow openings or ducted delivery can help adjacent rooms receive gas. Adding another machine at the same blocked location may increase local pressure without helping the room where Duplicants are struggling.
Keep algae delivery practical. The diffuser creates a life-support supply errand when its stock falls, so labor and access matter. A large algae pile in an inaccessible location does not replenish the building.
2. Monitor the Algae Reserve
Diffusers use algae quickly. Inspect the reserve and how much accessible algae remains in explored areas. The right time to research an alternative is before the final stack disappears, not after the machine has already stopped.
Keep colony growth aligned with supply. Printing another Duplicant because a bed is available can turn a manageable oxygen system into a resource race. Decide whether water, food, labor and heat control can support the new person together.
If a diffuser stops with algae available, inspect its status. It stops under excessive local gas pressure, and the gas causing that pressure need not be oxygen. Diagnose the surrounding gas before assuming the building needs more raw material.
3. Build a Water-Fed Electrolyzer as a Complete System
An Electrolyzer consumes one kilogram of water per second and produces 888 grams of oxygen plus 112 grams of hydrogen while operating. It requires electricity and a piped supply of the correct water type.
Polluted Water is not an interchangeable input. The source page warns that incorrect liquid damages the machine. Inspect the pipe contents and treatment chain before connecting a mixed reservoir directly.
Reliable water means more than having one pool today. Consider the pool’s volume, other consumers and any continuing source you intend to use. A geyser also has an output pattern, so storage and periods of inactivity matter to a long-term supply.
The oxygen output can theoretically cover more than eight normal Duplicants at full uptime. Build margin for real operation and distribution instead of increasing population directly to the numerical limit.
4. Separate Hydrogen from the Breathable Supply
The Electrolyzer produces both gases. Hydrogen rises and can be collected near the ceiling, while oxygen is routed toward the colony. A dedicated production room can make this easier to control.
A gas filter is a straightforward separation tool, though designs can also use carefully arranged gas behavior. Use a design you understand rather than copying a compact advanced setup whose failure state you cannot diagnose.
Send hydrogen to an appropriate consumer or storage route. If an output backs up, production or pumping can stop. A system must have somewhere for both gases to go, including a plan for demand changes.

5. Plan Heat Before Feeding the Base
Electrolyzer oxygen and hydrogen have a minimum output temperature of 70 degrees Celsius according to the wiki, and hotter inputs can make them hotter. Cold water therefore does not automatically produce cold breathing gas.
Keep the production heat away from sensitive farms and bedrooms. Cool the delivered oxygen or control the inhabited area’s temperature through a suitable cooling system. Our heat management guide explains the difference between moving heat and removing it.
Cooling water far below what the machine needs can consume effort while the output still begins at its minimum gas temperature. The source discusses cooling gas after production because its heat capacity differs from the input water. Choose the cooling target deliberately.
6. Check Pumps, Vents and Pressure
A sealed production room needs gas removal fast enough to keep the Electrolyzer operating. If local pressure reaches its limit, the machine idles even with correct water and power. Inspect production-room pressure and pump status.
Normal vents also stop when their destination pressure is too high. Multiple delivery points can help distribute oxygen, but they still need appropriate room connections and a usable destination. High-pressure vents require a deliberate pressure plan rather than automatic use everywhere.
For suit systems, inspect dock delivery separately from room breathing. A healthy base atmosphere does not fill a disconnected suit dock. Follow the actual gas pipe and its consumer.
7. Keep a Practical Transition Margin
Do not dismantle the working early supply before the replacement can operate. Test the new water, power, separation and delivery paths, then reduce algae use once the colony receives stable oxygen.
The Oxygen Not Included beginner guide covers the wider colony priorities. An oxygen upgrade is useful when its water and heat demands fit that broader plan.
Frequently Asked Questions
How many normal Duplicants can a diffuser supply?
Its full 500-grams-per-second output equals five standard 100-grams-per-second consumers. Actual uptime, traits and gas access require additional planning.
Why does the Electrolyzer stop with water available?
Check power, pipe contents, flooding and local gas pressure. Correct water alone does not guarantee operation.
Does cold input water make cold oxygen?
No. The documented Electrolyzer output has a 70-degree-Celsius minimum. Plan cooling or isolate the resulting heat.
Next step: Measure the colony’s actual demand, inspect the current machine’s downtime and solve the limiting input or delivery step before adding more people.
Sources and Version Notes
- Official Oxygen Not Included Wiki: Oxygen Diffuser
- Official Oxygen Not Included Wiki: Electrolyzer output and temperature
- Official Oxygen Not Included Wiki: oxygen and Duplicant consumption
- Official Oxygen Not Included Wiki: heat transfer and deletion
Sources read November 11, 2026. Platform features refer to the named edition; this is source-backed guidance, not a personal playtest.
