Oxygen Not Included Heat Management: Move It, Then Remove It

Manage Oxygen Not Included heat by separating hot equipment from sensitive rooms, insulating unwanted heat paths, and moving heat into a cooling system with a real removal sink. Check where the heat goes before expanding the loop.

Official Oxygen Not Included colony screenshot from the Steam store gallery
Official Oxygen Not Included game screenshot. Source: Oxygen Not Included on Steam. © the game’s respective rights holders.

TL;DR: Keep hot machinery away from farms and inhabited rooms, insulate the boundary, and use coolant to move heat toward a controlled sink. A Thermo Aquatuner lowers liquid temperature by 14 degrees Celsius while transferring that heat into itself and its surroundings. It does not delete heat alone. A properly operated Steam Turbine can remove heat from steam, but the turbine needs its own cooling and usable output path.

This Oxygen Not Included heat management guide explains the system before recommending compact machinery. Asteroid resources, DLC and available materials change the practical build, while the distinction between storing, moving and deleting heat remains essential.

Official Oxygen Not Included colony screenshot from the Steam store gallery
Official Oxygen Not Included game screenshot. Source: Oxygen Not Included on Steam. © the game’s respective rights holders.

Oxygen Not Included Heat Management: Find the Source

Use the temperature overlay to locate warming areas, then inspect the machines, pipes and materials nearby. A hot farm may be receiving heat from delivered oxygen, industrial equipment or a neighboring biome. Cooling the farm without addressing that source can become an endless maintenance task.

Watch change over time. One warm tile may be harmless, while a large reservoir slowly heating can become a long-term problem. Identify whether the temperature is stable or still rising before deciding the scale of the solution.

Separate immediate protection from permanent cooling. Moving a sensitive crop away from a heat source can protect food production while you build a more complete loop. A temporary measure is useful when you understand its limited role.

1. Isolate Hot Processes

Place industrial heat sources in a region designed to absorb and handle their output. Power generation and refining do not need to share the farm’s comfortable temperature merely because a nearby empty room is convenient.

Use insulated tiles and insulated pipes where you want to reduce heat transfer. Insulation slows exchange; it does not remove existing heat from the enclosed area. A sealed hot room still needs a plan for increasing temperature.

Check doors, ordinary pipe segments and other bridges across the boundary. A mostly insulated design can still exchange heat through a small overlooked path. Inspect the whole connection rather than declaring the wall material alone sufficient.

2. Understand Thermal Mass as a Buffer

A large body of liquid or cold biome can absorb heat while changing temperature relatively slowly. That can be a useful early buffer. Its stored cold is finite unless another process restores the balance.

If the receiving mass keeps warming, you are spending that buffer. Plan the later removal method before it reaches the temperature limit of nearby crops or equipment. “It worked for several cycles” is not proof of a permanent heat sink.

Materials differ in specific heat capacity and thermal conductivity. The first affects how much heat changes their temperature; the second affects how readily heat moves. Choose a coolant and transfer surface for those roles rather than using temperature alone as the comparison.

3. Use Pipe Materials for the Intended Exchange

Radiant pipes are useful where coolant should exchange heat with the surrounding area. Insulated pipes are useful while transporting it through places you do not want to heat or cool. Ordinary segments may be adequate in less demanding parts of a system.

Route the cooling loop through the area you actually need to control. A cold liquid passing in an insulated pipe has limited ability to cool the room around it. Conversely, a radiant return pipe through a farm can transfer unwanted heat back into that farm.

Inspect liquid temperature along the route. The difference between entry and exit helps show where exchange occurs. A loop can circulate perfectly while missing the intended heat source.

4. An Aquatuner Moves Heat into Its Surroundings

The Thermo Aquatuner reduces each liquid packet by 14 degrees Celsius and requires 1.2 kilowatts while operating. The amount of heat moved depends on the packet mass and the coolant’s specific heat capacity.

The removed heat enters the Aquatuner itself. Its surroundings must absorb that heat, or the machine overheats. The wiki therefore recommends suitable materials and a heat-transfer environment rather than operating a full-time tuner in a poorly exchanging gas pocket.

Do not cool the Aquatuner with its own output and assume the entire system gains free cold. Without another source or sink, the machine has transferred heat inside the same system. Trace where the heat ultimately leaves.

Use temperature control to avoid sending coolant below its freezing point. The Aquatuner does not protect the output pipe from phase-change damage. A sensor and bypass need to maintain flow while skipping cooling when it is not required.

Official Oxygen Not Included colony screenshot from the Steam store gallery
Official Oxygen Not Included game screenshot. Source: Oxygen Not Included on Steam. © the game’s respective rights holders.

5. Pair Heat Transfer with a Usable Sink

A common later approach transfers Aquatuner heat into a steam chamber and uses a Steam Turbine above it. The turbine consumes suitably hot steam and outputs water, deleting much of the heat through its operation.

The documented steam requirement begins at 125 degrees Celsius, while output water is 95 degrees. The turbine’s own building temperature must remain below 100 degrees for operation. That operating limit is different from its much higher damage-overheat temperature.

If the turbine becomes too warm and stalls, it stops removing the chamber’s heat. Continuing to run the hot process below can make recovery harder. Provide turbine cooling and watch its actual status before assuming the chamber is controlled.

Keep the water output and steam inlets usable. A blocked output or inaccessible steam is a machine-operation problem, not evidence that the heat-transfer principle has failed.

6. Protect the Oxygen Delivery Route

Electrolyzers produce oxygen and hydrogen at a minimum of 70 degrees Celsius according to the source. Delivering that gas directly through sensitive crops can create heat trouble even when the breathing supply is generous.

Choose whether to cool the gas before delivery or maintain the base with a separate cooling system. Our oxygen production guide explains why cold input water does not automatically produce cold breathing gas.

Keep the cooling target proportionate. Cooling a large input-water mass unnecessarily can consume effort while the machine still applies its output minimum. Follow the heat capacity and the destination’s actual requirements.

7. Test the Loop Under Continuing Load

Inspect coolant circulation, controlled temperatures and the heat sink while the source machinery operates. A system that stabilizes an empty chamber may behave differently when refining or oxygen production runs continuously.

Look for rising temperature, broken pipes, intermittent flow and a stalled turbine. Fix one identifiable limiting step, then observe the result. Keep access for repair rather than hiding every component inside an inaccessible compact build.

The beginner guide covers the broader priorities. Stable food and oxygen often deserve immediate protection while you prepare the advanced cooling materials and power.

Frequently Asked Questions

Does an Aquatuner delete heat?

No. It transfers heat from the liquid into the machine and its surroundings. A real sink is needed for continuing heat removal.

Why does a turbine stop below its damage temperature?

Its operating condition requires the building to remain below 100 degrees Celsius. Stalling is separate from damaging overheat.

Is a cold biome a permanent cooling solution?

It is a finite thermal buffer unless its heat balance is restored. Monitor warming and prepare a continuing removal method when needed.

Next step: Trace one hot area from source to destination and identify where its heat is stored, transferred and finally removed. Solve that full path before expanding the hot machinery.

Sources and Version Notes

Sources read November 11, 2026. Platform features refer to the named edition; this is source-backed guidance, not a personal playtest.

Sources and further reading